12/22/2024 2:22 p.m.
https://cablematic.com/en/products/electrical-box-spn-8m-ip65-abs-plastic-surface-ha-MF012/
https://cablematic.com/en/products/electrical-box-spn-8m-ip65-abs-plastic-surface-ha-MF012/
Electrical box SPN 8M IP65 ABS plastic surface HA
REF: MF012
Specifications
- Distribution box plABS plastic with IP65 environmental protection.
- Made of sturdy gray ABS plastic.
- Compatible with the IEC60670-24 standard.
- Maximum intensity: 100A.
- Operating voltage: 240/415V.
Watch video
PVP
€8.51
Price including VAT:
€8.51
PVD
€7.25
PVP: Retail price.
Check conditions.
PVP: Sale price to distributors.
Check conditions.
Buy before:
Receive it:
Friday 27
Delivery times are approximate. Cablematic is not responsible for delays.
2 years
warranty
warranty
14 days
returns
returns
100%
safe
safe
Specifications
- Distribution box plABS plastic with IP65 environmental protection.
- Made of sturdy gray ABS plastic.
- Compatible with the IEC60670-24 standard.
- Maximum intensity: 100A.
- Operating voltage: 240/415V.
Keywords
Did not find what you were looking for? These topic could help you
More info
ABS plastic surface distribution box, with 8 modules in line. The distribution box allows the assembly of standard modules 18mm wide, on a DIN rail. Robust distribution box made of plastic. Designed to be installed on a flat surface. Electric distribution box with IP65 environmental protection, water resistant.
Specifications
Specifications
- Distribution box plABS plastic with IP65 environmental protection.
- Made of sturdy gray ABS plastic.
- Compatible with the IEC60670-24 standard.
- Maximum intensity: 100A.
- Operating voltage: 240/415V.
- 35x7mm DIN rail for fixing the modules.
- Transparent front door obscured to protect the modules.
- Opening of the door to the side (horizontal rotation).
- Fixing to wall using screws (not included). It is fixed directly to the surface.
- Model for the installation of 8 standard 18mm wide modules.
- It is supplied with 4 plugged modules and 4 open modules.
- Size of the module window: 144 x 47 mm.
- Distribution box size: 205 x 210 x 100 mm.
- Gross Weight: 730 g
- Product size (width x depth x height): 21.3 x 20.5 x 10.0 cm
- Number of packages: 1
- Packages size: 22.5 x 21.5 x 10.5 cm
- Master-pack: 20
Technical terms
- IP65
- DIN
- SPN
- DIN Rail
- IP Protection
- ABS
IP65
IP65 Although it seems very complicated nomenclature IP standards is only one division in two digits, where each digit indicates that it is being served to meet these regulations. For the first digit would be: 0 No protection 1 element to be used for testing (sphere 50 mm in diameter) should not get to go completely. 2 element to be used for the test (area of ??12.5 mm diameter) should not get to go completely. 3 element to be used for testing (sphere 2.5 mm in diameter) must not come at all. 4 element to be used for the test (sphere of 1 mm in diameter) must not come at all. 5 ingress of dust can not be avoided, but it must not enter an amount that interferes with the proper functioning of equipment. 6 polvo should not come under any circumstances in the case of the second digit: Level Protection Against Expected Results Test Method 0 The water enters the equipment quickly. 1 The equipment is placed in their usual work. Should not enter the water when it is dropped from 200 mm height from the team for 10 minutes (at a rate of 3-5 mm³ per minute) 2, the equipment is put into lugar normal work. You should not enter the water when the leaves fall, for 10 minutes (at a rate of 3-5 mm³ per minute). This test should be performed four times at a rate of one for every 15 ° rotation both vertically and horizontally, starting each time the normal position. 3 The equipment is placed in their usual work. You should not enter the water spray at an angle up to 60 ° right and leftvertically to an average of 10 liters per minute and a pressure of 80-100kN/m for a time not less than 5 minutes. 4 The equipment is placed in their usual work. You should not enter the water thrown from any angle to an average of 10 liters per minute and a pressure of 80-100kN/m for a time not less than 5 minutes. 5 The equipment is placed in their usual work. Should not enter waterthrown jet (from any angle) by means of a nozzle 6.3 mm in diameter, at an average of 12.5 liters per minute and a pressure of 30 kN/m for a time not less than 3 minutes and a no closer than 3 meters. 6 The equipment is placed in their usual work. You should not enter water squirted (from any angle) through a nozzle diameter of 12.5 mm, an average of 100 liters per minute and a pressure of 100 kN/m² for at least three minutes at a distance of not less than 3 meters. 7 The object must endure without any filtration complete immersion in 1 meter for 30 minutes. 8 electrical/electronic equipment must withstand (without filtration) complete and continuous immersion depth and during the time specified by the manufacturer of the product with the agreement ofclient, but provided they are more severe than those specified for the value 7. For IP65 should meet the following standard conditions. Would hold cirscuntancias be dusty and prevent to enter under any cirscuntacia, and bear no powerful jets of water.