04/19/2024 6:34 a.m.
https://cablematic.com/en/products/adapter-cable-compatible-with-tamiya-male-to-minitamiya-male-crossed-200mm-TY025/
https://cablematic.com/en/products/adapter-cable-compatible-with-tamiya-male-to-minitamiya-male-crossed-200mm-TY025/
Adapter cable compatible with Tamiya male to MiniTamiya male crossed 200mm
REF: TY025
Specifications
- Cable based on Tamiya connectors used in modeling for connection of electrical circuits and battery banks.
- It is a cable based on Tamiya Male connector on one end and Mini-Tamiya Male connector on the other end.
- UL 1015 quality cable of red / black colors and section 14AWG.
- 200 mm cable length.
- Cable with crossed polarity.
Watch video
PVP
€0.39
Price including VAT:
€0.39
PVD
€0.34
PVP: Retail price.
Check conditions.
PVP: Sale price to distributors.
Check conditions.
Buy before:
Receive it:
Thursday 25
Delivery times are approximate. Cablematic is not responsible for delays.
2 years
warranty
warranty
14 days
returns
returns
100%
safe
safe
Specifications
- Cable based on Tamiya connectors used in modeling for connection of electrical circuits and battery banks.
- It is a cable based on Tamiya Male connector on one end and Mini-Tamiya Male connector on the other end.
- UL 1015 quality cable of red / black colors and section 14AWG.
- 200 mm cable length.
- Cable with crossed polarity.
Keywords
Did not find what you were looking for? These topic could help you
More info
Cable based on Tamiya connectors used in modeling for connection of electrical circuits and battery banks. It is a cable based on Tamiya Male connector on one end and Mini-Tamiya Male connector on the other end. UL 1015 quality cable of red / black colors and section 14AWG. 200 mm cable length. Cable with crossed polarity.
- Gross Weight: 10 g
- Number of packages: 1
Technical terms
- AWG (Measurement of electrical cables)
- Tamiya
- Battery charging cycles
AWG (Measurement of electrical cables)
AWG stands for "American Wire Gauge" being this a measure used to represent the width and section measurements of cables.
Here is an AWG conversion table:
Here is an AWG conversion table:
AWG | Diam. mm | Mm2 area | AWG | Diam. mm | Mm2 area | |
1 | 7.35 | 42.40 | 16 | 1.29 | 1.31 | |
two | 6.54 | 33.60 | 17 | 1.15 | 1.04 | |
3 | 5.86 | 27.00 | 18 | 1,024 | 0.823 | |
4 | 5.19 | 21.20 | 19 | 0.912 | 0.653 | |
5 | 4.62 | 16.80 | twenty | 0.812 | 0.519 | |
6 | 4.11 | 13.30 | twenty-one | 0.723 | 0.412 | |
7 | 3.67 | 10.60 | 22 | 0.644 | 0.325 | |
8 | 3.26 | 8.35 | 2. 3 | 0.573 | 0.259 | |
9 | 2.91 | 6.62 | 24 | 0.511 | 0.205 | |
10 | 2.59 | 5.27 | 25 | 0.455 | 0.163 | |
eleven | 2.30 | 4.15 | 26 | 0.405 | 0.128 | |
12 | 2.05 | 3.31 | 27 | 0.361 | 0.102 | |
13 | 1.83 | 2.63 | 28 | 0.321 | 0.0804 | |
14 | 1.63 | 2.08 | 29 | 0.286 | 0.0646 | |
fifteen | 1.45 | 1.65 | 30 | 0.255 | 0.0503 |