https://cablematic.com/en/products/digital-clamp-meter-acdc-1000a-TM001/
Digital clamp meter AC/DC 1000A
- Maximum opening of up to 58 mm.
- Automatic indication of functions and units of measurement.
- Maximum current supports 1000 A in AC.
- Maximum voltage of 600 V in AC and 600 V in DC.
- Automatic zeroing.
Watch video
More info
warranty
returns
safe
- Maximum opening of up to 58 mm.
- Automatic indication of functions and units of measurement.
- Maximum current supports 1000 A in AC.
- Maximum voltage of 600 V in AC and 600 V in DC.
- Automatic zeroing.
Keywords
Did not find what you were looking for? These topic could help you
More info
Digital multimeter to clamp to measure resistance, voltage, capacity and frequency. Model that supports a maximum intensity of 1000 A in AC current. Supports 600 V in AC and 600 V in DC. Model made of quality materials that comes in comfortable black canvas bag.
Specifications
- Maximum opening of up to 58 mm.
- Automatic indication of functions and units of measurement.
- Maximum current supports 1000 A in AC.
- Maximum voltage of 600 V in AC and 600 V in DC.
- Automatic zeroing.
- Overload indicator in the viewfinder.
- Check of ACV, ACA, DCV, Ohm and continuity.
- Size: 230 x 70 x 37 mm.
- Supplied with black canvas carrying case.
- Conforming standard: IEC-61010-1, 2000 CAT II 600V.
- Works with a 9VDC batteryof type 6F22 (included).
- Gross Weight: 410 g
- Product size (width x depth x height): 23.0 x 9.0 x 4.0 cm
- Number of packages: 1
- Packages size: 25.0 x 12.5 x 5.0 cm
Technical terms
- Impedance
Impedance (Z) is the total opposition that a circuit offers to alternating current (AC) flow when a specific voltage is applied.
Unlike simple resistance, impedance is a complex quantity comprising resistance (the real part) and reactance (the imaginary part, representing inductive or capacitive effects). In the frequency domain, impedance is represented as a phasor, accounting for both magnitude and phase shift between voltage and current. In DC circuits, impedance reduces to pure resistance with zero phase angle.
| Parameter | Technical Spec |
|---|---|
| Symbol | Z |
| Unit | Ohm (Ω) |
Impedance management is critical in high-speed hardware design and signal integrity. In modern PCB manufacturing, controlled impedance ensures that high-frequency signals reach their destination without reflections, which is vital for PCIe or DDR5 performance.
Complex Domain Analysis
Mathematical modeling of impedance using the j-operator allows engineers to optimize filter performance and resonance characteristics in electronic systems.
Key Advantages
- Maximum power transfer through impedance matching.
- Minimized signal reflections in high-frequency transmission lines.
- Improved electromagnetic compatibility (EMC).
Note: Impedance is the cornerstone of modern AC circuit theory and high-frequency design.