Slim 1U CPU Cooler (Socket LGA775 PIV-3200E)
REF: VU014
Specifications
  • Compatible Pentium 4 Socket LGA775.
  • Projector speed up to 3.2GHz.
  • Total Size: 89 x 86 x 28 mm.
  • Weight: 460 g
  • Manufactured in C1020 copper.
More info
PVP 26.76
7.23
Price including VAT: 7.23
PVD 23.53
6.35
2 years
warranty
14 days
returns
OUTLET

Out of stock

We will notify you when it is back in stock.
More info
Specifications
  • Compatible Pentium 4 Socket LGA775.
  • Projector speed up to 3.2GHz.
  • Total Size: 89 x 86 x 28 mm.
  • Weight: 460 g
  • Manufactured in C1020 copper.

More info

Radiator fan made entirely of copper C1020 to be installed in an Intel Pentium 4 Socket LGA775 processor (up to 3.2GHz). Ideal to be installed on servers 1U high.


Specifications
  • Compatible Pentium 4 Socket LGA775.
  • Projector speed up to 3.2GHz.
  • Total Size: 89 x 86 x 28 mm.
  • Weight: 460 g
  • Manufactured in C1020 copper.
  • Separation betweenslats: 1.3 mm.
  • Copper plate thickness: 0.4 mm.
  • Radiator size: 89 x 86 x 13 mm.
  • Fan size: 70 x 70 x 45 mm.
  • Fan speed: 5800 RPM.
  • Fan with lateral expulsion of air.
  • Voltage: 12VDC (4-pin connector).
  • Air flow: 10,489 CFM.
  • Noise level: 45.8 dBA.
  • Air pressure: 1.234 "- H2O
  • Gross Weight: 570 g
  • Product size (width x depth x height): 8.9 x 8.6 x 1.3 cm
  • Number of packages: 1
  • Packages size: 10.8 x 10.1 x 5.0 cm
  • Master-pack: 20

Technical terms

  • Rack unit (U)
  • Revolutions per minute (rpm)
Rack unit (U)
There are several cabinet heights according to the needs of the installation, this height can be measured in rack units (U).

Each rack unit or U is the distance between each horizontal separation to place the different accessories inside the rack. This distance is 1.75 inches that is equal to 4.4445 cm high.

For example, if we say that a rack is 8U we will understand that it has 8 units to install device orAccessories of 4.44 cm in height.

Normally these accessories, like trays, guides, strips, etc. Occupy a unit of U (1U), but we can find that other devices or accessories occupy more units, for example can be a rack box to install a PC, a UPS, etc. It can be said that there is also a half unit of U (0.5U), in this case, two units could be installed in a rack unit.

As far as I knowEndo the units of rack that occupy the devices that we are going to install we will know the height that we need for our rack.

The size of the rack unit (U) is based on the standard specification for racks defined in EIA-310.