11/08/2024 4:47 p.m.
https://cablematic.com/en/products/adapter-cable-compatible-with-tamiya-male-to-minitamiya-female-346-mm-TY023/
https://cablematic.com/en/products/adapter-cable-compatible-with-tamiya-male-to-minitamiya-female-346-mm-TY023/
Adapter cable compatible with Tamiya male to MiniTamiya female 346 mm
REF: TY023
OUTLET
Specifications
- Cable based on Tamiya connectors used in modeling for connection of electrical circuits and battery banks.
- It is a cable based on a Tamiya male connector on one end and a Mini-Tamiya female connector on the other end.
- UL 1015 quality cable of red / black colors and section 16AWG.
- Cable length of 346 mm.
PVP
€0.39
€0.24
Price including VAT:
€0.24
PVD
€0.34
€0.21
PVP: Retail price.
Check conditions.
PVP: Sale price to distributors.
Check conditions.
Buy before:
Receive it:
Friday 15
Delivery times are approximate. Cablematic is not responsible for delays.
2 years
warranty
warranty
14 days
returns
returns
OUTLET
Specifications
- Cable based on Tamiya connectors used in modeling for connection of electrical circuits and battery banks.
- It is a cable based on a Tamiya male connector on one end and a Mini-Tamiya female connector on the other end.
- UL 1015 quality cable of red / black colors and section 16AWG.
- Cable length of 346 mm.
Keywords
Did not find what you were looking for? These topic could help you
More info
Cable based on Tamiya connectors used in modeling for connection of electrical circuits and battery banks. It is a cable based on a Tamiya male connector on one end and a Mini-Tamiya female connector on the other end. UL 1015 quality cable of red / black colors and section 16AWG. Cable length of 346 mm.
- Gross Weight: 20 g
- Product size (width x depth x height): 1.8 x 34.6 x 1.0 cm
- Number of packages: 1
- Packages size: 1.8 x 34.6 x 1.0 cm
Technical terms
- AWG (Measurement of electrical cables)
- Tamiya
- Battery charging cycles
AWG (Measurement of electrical cables)
AWG stands for "American Wire Gauge" being this a measure used to represent the width and section measurements of cables.
Here is an AWG conversion table:
Here is an AWG conversion table:
AWG | Diam. mm | Mm2 area | AWG | Diam. mm | Mm2 area | |
1 | 7.35 | 42.40 | 16 | 1.29 | 1.31 | |
two | 6.54 | 33.60 | 17 | 1.15 | 1.04 | |
3 | 5.86 | 27.00 | 18 | 1,024 | 0.823 | |
4 | 5.19 | 21.20 | 19 | 0.912 | 0.653 | |
5 | 4.62 | 16.80 | twenty | 0.812 | 0.519 | |
6 | 4.11 | 13.30 | twenty-one | 0.723 | 0.412 | |
7 | 3.67 | 10.60 | 22 | 0.644 | 0.325 | |
8 | 3.26 | 8.35 | 2. 3 | 0.573 | 0.259 | |
9 | 2.91 | 6.62 | 24 | 0.511 | 0.205 | |
10 | 2.59 | 5.27 | 25 | 0.455 | 0.163 | |
eleven | 2.30 | 4.15 | 26 | 0.405 | 0.128 | |
12 | 2.05 | 3.31 | 27 | 0.361 | 0.102 | |
13 | 1.83 | 2.63 | 28 | 0.321 | 0.0804 | |
14 | 1.63 | 2.08 | 29 | 0.286 | 0.0646 | |
fifteen | 1.45 | 1.65 | 30 | 0.255 | 0.0503 |